Adjustable Finger Clip Blood Oxygen Sensor for Adult Pulse Oximeter Monitoring Probes

27,95 €
+ 13,49 € Versand

Adjustable Finger Clip Blood Oxygen Sensor for Adult Pulse Oximeter Monitoring Probes

  • Marke: Unbranded
Verkauft von:

Adjustable Finger Clip Blood Oxygen Sensor for Adult Pulse Oximeter Monitoring Probes

  • Marke: Unbranded
UPE: 69,00 €
Preis: 27,95 €
Sie sparen: 41,05 € (59%)
Verkauft von:
27,95 €
+ 13,49 € Versand

Auf Lager

Wir akzeptieren die folgenden Zahlungsmethoden

Beschreibung

Item Type: Blood Oxygen Probe Material: Plastic Compatible with CSI models only Specification: LED 660nm/905nm/940nm Maximum Output Power: 15 mW For adult use only, body weight >40kg; designed to be clamped on the index finger or any finger SpO2 Measurement Range: 70%–100% SpO2 Accuracy: ±2% when SpO2 is 90%–100%, ±3% when SpO2 is 70%–89% Pulse Rate Measurement Range: 30–245 bpm Pulse Rate Accuracy: ±3 bpm Main Components: Plug, cable, and probe Intended Use: For use with pulse oximeters and multi-parameter monitors to non-invasively monitor pulse rate and blood oxygen saturation in adult patients (body weight >40kg). Not intended for use under conditions of weak perfusion or motion. Not suitable for long-term continuous monitoring; reposition or inspect the probe site every 4 hours or alternate between fingers. Contraindications: Do not use on tissue-damaged areas. Not suitable for individuals with known sensitivity to PVC, TPU, TPE, or ABS plastics. Warnings: A) Improper placement may result in inaccurate readings. B) Excessive ambient light may interfere with measurement. Shield the sensor with an opaque material if necessary. C) Reposition the probe to a different site at least every 4 hours. Skin condition should be monitored; if skin integrity is compromised, move the probe immediately. D) Presence of intravascular dyes may affect measurement accuracy. E) Motion artifacts may impact performance; not recommended for highly active or restless patients. F) Avoid over-tightening the probe. Excessive pressure may cause venous pulsation and inaccurate readings. G) Route cables carefully to prevent entanglement or patient entrapment. H) Do not use during MRI procedures. Metallic components may cause burns and interfere with imaging. The MRI environment may also affect device performance. I) Do not modify or alter the device. Unauthorized changes may impair function or safety. J) Do not sterilize using radiation, steam, or ethylene oxide without following validated protocols. K) Do not immerse in liquids for cleaning or disinfection. L) Radiofrequency interference from mobile phones or wireless devices may affect sensor operation. Instructions for Use: 1) Insert the fingertip into the sensor until it reaches the stop. Ensure the nail is not excessively long to allow proper contact. 2) Open the lower cover of the finger clamp to ensure even pressure across the padding. 3) Verify correct sensor placement. If the index finger is unsuitable, use another finger. Avoid use on thumbs, toes, hands, or feet in pediatric patients. Note: Choose a monitoring site free from arterial lines, blood pressure cuffs, or IV infusions. 4) Route the cable along the back of the hand to minimize movement. 5) Connect the probe to the compatible oximeter and follow the manufacturer’s operating instructions. Note: If pulse detection is inconsistent, check sensor placement. Thick, thin, or heavily pigmented fingers may impair signal. Reposition or select an alternative sensor type if needed. Maintenance, Cleaning, and Disinfection: A) Inspect for damage and cleanliness before each use. B) Cleaning: Wipe with a soft cloth dampened with mild detergent or soapy water. Dry thoroughly after cleaning. C) Disinfection: Use chemical disinfectants such as ethanol, propanol, or phenol-based solutions. Do not immerse in liquid. Avoid prolonged exposure to UV light. D) Sterilization: If required, use ethylene oxide (EtO) gas at a maximum temperature of 50°C (122°F). Follow aeration guidelines per sterilization equipment instructions. Replacement: Replace every 6 months with regular use. If continued use is necessary, inspect frequently for wear or damage. Storage: After cleaning, disinfecting, and drying, store in a sealed plastic bag. Environmental Conditions: Operating Temperature: 10°C to 40°C (50°F to 104°F) Storage Temperature: -20°C to 60°C (-4°F to 140°F) Operating Humidity: 15% to 90% relative humidity, non-condensing Storage Humidity: 10% to 95% relative humidity, non-condensing
  • Fruugo-ID: 404682635-858772697
  • EAN: 9347182635387

Produktsicherheitsinformationen

Bitte beachten Sie die unten aufgeführten spezifischen Produktsicherheitsinformationen für dieses Produkt

Die folgenden Informationen werden vom unabhängigen Drittanbieter bereitgestellt, der dieses Produkt verkauft.

Sicherheitswarnungen: Do not let your children touch this product alone to avoid swallowing or other injuries.

Lieferung und Rückgaben

Versand innerhalb von 24 Stunden

  • STANDARD: 13,49 € - Lieferung zwischen Mo. 27 Oktober 2025–Di. 04 November 2025

Versand von China.

Wir tun unser Bestes, um dafür zu sorgen, dass die von Ihnen bestellten Produkte vollständig und gemäß Ihrer Spezifikationen an Sie geliefert werden. Wenn Sie allerdings eine unvollständige Bestellung oder Artikel erhalten, die sich von den bestellten unterscheiden, oder es einen anderen Grund gibt, warum Sie mit Ihrer Bestellung nicht zufrieden sind, können Sie die gesamte Bestellung oder einzelne darin enthaltenen Produkte zurücksenden und eine vollständige Rückerstattung für die Artikel erhalten. Vollständige Rückgaberichtlinie ansehen

Details zur Produktkonformität

Bitte beachten Sie die unten aufgeführten Konformitätsinformationen zu diesem Produkt.

Die folgenden Informationen werden vom unabhängigen Drittanbieter bereitgestellt, der dieses Produkt verkauft.

Hersteller:
Es folgen die Kontaktdaten für den Hersteller des jeweiligen Produkts, das auf Fruugo verkauft wird.

  • Qiu Jiateng
  • Wuhan Lili Xing Trading Co., Ltd
  • 9 Jian She 2nd Road, Building 6, Unit, Floor 7, No. 11 Yu Jiang Yi Pin · Qing Shan Yin, Qingshan District, Hubei
  • Wuhan
  • CN
  • 430080
  • jing4808880meif@163.com
  • 15625617190

Verantwortliche Person in der EU:
Es folgen die Kontaktinformationen für die verantwortliche Person in der EU. Die verantwortliche Person ist der benannte Wirtschaftsteilnehmer mit Sitz in der EU und verantwortlich für die Compliance-Verpflichtungen in Verbindung mit dem jeweiligen Produkt, das in die Europäische Union verkauft wird.

  • Van Lavazza
  • Y & H S.R.L.
  • Via Gravina 21 MT matera,Trani,Puglia
  • Trani
  • Italy
  • 75100
  • itlyhsrl@gmail.com
  • 0039 3917722149