Description
Stepper Motor Driver Digital Display 42 57 Step Motor Drive Controller 5V‑24V DM542L
Item Type: Stepper Motor Driver
Parameter: DM542L
Minimum Continuous Output Current: 1A
Maximum Continuous Output Current: 4.2A
Minimum Logic Input Current: 7mA
Typical Logic Input Current: 10mA
Maximum Logic Input Current: 20mA
Maximum Power of The Whole Machine: 100W
Pulse Frequency: 0-200kHz
Minimum Insulation Resistance: 500MΩ
Maximum Logic Current of Digital Output Port: 100mA
Cooling Mode: Natural cooling or external radiator.
Usage: Avoid dust, oil mist and corrosive gas.
Temperature: 0℃ - 50℃
Ambient Humidity: 40-90% RH
Operating Environment Vibration: 10~55Hz/0.15mm
Storage Temperature: -20℃- +65 ℃
Interface definition:
Terminal 1 Symbol: A+
Terminal 1 Name: A Phase Motor Winding+
Terminal 1 Wire Color Description:
Terminal 2 Symbol: A-
Terminal 2 Name: A Phase Motor Winding-
Terminal 2 Wire Color Description:
Terminal 3 Symbol: B+
Terminal 3 Name: B Phase Motor Winding+
Terminal 3 Wire Color Description:
Terminal 4 Symbol: B-
Terminal 4 Name: B Phase Motor Winding-
Terminal 4 Wire Color Description:
Terminal 5 Symbol: VCC
Terminal 5 Wire Color Description: 18-48V DC
Terminal 6 Symbol: GND
Terminal 6 Wire Color Description: 18-48V DC
Control Signal Terminal:
Terminal 1 Symbol: DIR-
Terminal 1 Name: Direction Negative Input
Terminal 1 Description: Signal source +5V~24V universal, no need to connect resistance in series.
Terminal 2 Symbol: DIR+
Terminal 2 Name: Direction Positive Input
Terminal 2 Description: Signal source +5V~24V universal, no need to connect resistance in series.
Terminal 3 Symbol: PUL-
Terminal 3 Name: Pulse Negative Input
Terminal 3 Description: Signal source +5V~24V universal, no need to connect resistance in series.
Terminal 4 Symbol: PUL+
Terminal 4 Name: Pulse Positive Input
Terminal 4 Description: Signal source +5V~24V universal, no need to connect resistance in series.
Terminal 5 Symbol: ENA-
Terminal 5 Name: Motor Enable Negative Input
Terminal 5 Description: When the signal is valid, the motor is in free state and does not stall.
Terminal 6 Symbol: ENA+
Terminal 6 Name: Motor Enable Positive Input
Terminal 6 Description: When the signal is valid, the motor is in free state and does not stall.
Terminal 7 Symbol: ALM-
Terminal 7 Name: Alarm Signal Negative Output
Terminal 8 Symbol: ALM+
Terminal 8 Name: Alarm Signal Positive Output
Fault Description:
Fault Coding 1: Er01
Fault Description 1: Motor Overcurrent
Solution 1: Return to factory for inspection.
Fault Coding 2: Er02
Fault Description 2: Drive Overvoltage
Solution 2: Detect whether the motor is short-circuited or reduce the current.
Fault Coding 3: Er03
Fault Description 3: Hardware Fault
Parameter Monitoring Description:
Function Coding 1: L-00
Function Description 1: Speed
Function Coding 2: L-01
Function Description 2: Pulse Speed
Function Coding 3: L-02
Function Description 3: Given Pulse Number
Function Coding 4: L-03
Function Description 4: Useless
Function Coding 5: L-05
Function Description 5: Driver Fault Coding
Function Introduction 5: Check the number of received pulses in real time to determine whether the motor is out of step.
Description of Common Function Coding:
Function Coding 1 Parameter Setting: Number of subdivided pulses.
Function Coding 1: P-02
Function Description 1: 200-51200 arbitrary setting, 2000 in default.
Function Coding 2 Parameter Setting: Open loop current percentage.
Function Coding 2: P-10
Function Description 2: 50%, 8A x 50%=4A
Function Coding 3 Parameter Setting: JOG operation.
Function Coding 3: JOG
Function Description 3: Enter JOG and press ▲▼ to jog.
Function Coding 4 Parameter Setting: Motor direction.
Function Coding 4: P-18
Function Description 4: 0 reverse, 1 forward.
Function Coding 5 Parameter Setting: Restore to default.
Function Coding 5: S-20
Function Description 5: Set to 1 to restore default settings.
Main Function Parameters of Zone P:
P-00: Current loop proportional gain P, 1~327671500
P-01: Current loop integral gain I, 2~32766200
P-02: Subdivision setting, 200~512002000
P-09: Percentage of holding current, 0~100, 40
P-10: Percentage of open-loop current, 0~100, 50
P-15: Pulse filter enable, 0~6, 0. 0: not enabled, 1: enabled.
P-16: Filtering time, 0~25600500Us
P-18: Motor running direction, 0~1, 1. 0: positive direction, 1: negative direction.
P-19: Internal pulse acceleration, 0-5000200.
P-20: Maximum speed, 0-3000100.
P-21: Stroke turns, 0-65535, 0.
P-22: Stroke pulse, 0-65535200
P-23: Reciprocating times, 0-200, 1.
P-24: Direction, 0-1, 1.
P-25: Interval, 0-3000000.
P-26: Reciprocating, 0-1, 1.
P-27: Whether the internal pulse is enabled, 0-1, 0. 0: pulse mode, 1: internal operation mode.
P-28: Internal pulse trigger operation, 0-1, 0. 1: Press the key to trigger operation. 2: External trigger operation, PUL+, PUL -. 3: External JOG, PUL+, PUL -, DIR+, DIR -.
P-29: Jog running speed, 0-300100.
Parameter Setting:
Current Ratio Function Coding: P-00
Current Ra
-
Fruugo ID:
388560857-833465598
-
EAN:
4621310502471
Delivery & Returns
Dispatched within 24 hours
Shipping from China.
We do our best to ensure that the products that you order are delivered to you in full and according to your specifications. However, should you receive an incomplete order, or items different from the ones you ordered, or there is some other reason why you are not satisfied with the order, you may return the order, or any products included in the order, and receive a full refund for the items. View full return policy